The LG DLG4871W is a 7.4 cubic foot electric dryer with advanced features including Sensor Dry technology, multiple drying cycles, steam refresh option, and smart diagnostics. This service manual provides comprehensive information for technicians including disassembly procedures, troubleshooting guides, wiring diagrams, and replacement part information for proper maintenance and repair.
Before performing any service procedures, ensure proper safety measures are followed.
| Hazard | Precaution |
|---|---|
| Electrical Shock | Disconnect power before servicing. Verify power is off with voltmeter. |
| High Temperature | Allow dryer to cool completely before disassembly. |
| Sharp Edges | Wear protective gloves when handling internal components. |
| Gas Leaks | Check all connections with leak detection solution if gas model. |
| Moving Parts | Ensure drum is stationary before beginning disassembly. |
Major components and their locations within the dryer assembly.
| Component | Location | Function |
|---|---|---|
| Control Board | Front console | Manages all dryer functions and cycles |
| Heating Element | Rear cabinet | Generates heat for drying process |
| Motor | Bottom front | Drives drum rotation and blower |
| Thermal Fuse | Exhaust duct | Safety device to prevent overheating |
| Moisture Sensor | Drum interior | Detects moisture levels for automatic drying |
| Belt | Drum to motor | Transfers motor power to drum |
| Idler Pulley | Under drum | Maintains belt tension |
Step-by-step instructions for accessing internal components.
WARNING! Always disconnect power and document wire connections before disassembly.
Wiring diagrams and electrical component testing procedures.
| Component | Test Procedure | Expected Values |
|---|---|---|
| Heating Element | Check continuity across terminals | 10-50 ohms |
| Thermal Fuse | Continuity test | 0 ohms (closed circuit) |
| Motor | Check windings resistance | 2-10 ohms between terminals |
| Thermostat | Continuity at room temperature | 0 ohms (closed) |
| Door Switch | Continuity with door closed | 0 ohms (closed) |
Procedures for diagnosing common dryer problems.
Common replacement parts with manufacturer part numbers.
| Part Description | Part Number | Notes |
|---|---|---|
| Heating Element | 5301EL1002A | Includes mounting hardware |
| Thermal Fuse | 5301EL2001B | Cutoff temperature 154°C |
| Drive Motor | 4681EL2002A | Includes motor pulley |
| Drive Belt | MDS45477401 | 4 rib, 89.5 inch |
| Door Switch | BCS30273001 | Normally open type |
| Control Board | 6871EL2002A | Main PCB assembly |
Proper procedures for reassembling dryer after service.
CAUTION! Ensure all safety devices are reinstalled and functioning properly.
Common error codes and their meanings for the DLG4871W model.
| Error Code | Description | Troubleshooting |
|---|---|---|
| tE | Thermistor error | Check moisture sensor connections |
| dE | Door switch error | Verify door switch operation |
| HE | Heating error | Check heating element and thermostats |
| LE | Motor error | Test motor and associated wiring |
| PF | Power failure | Reset dryer, check power supply |
Recommended maintenance intervals for optimal performance.