The LG Centrifugal Chiller is a high-efficiency cooling system designed for commercial and industrial applications, featuring advanced centrifugal compression technology, variable speed drive, integrated control system, multiple safety protections, energy optimization modes, remote monitoring capabilities, and environmentally friendly refrigerants. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Centrifugal compressor, Variable Speed Drive (VSD), Control panel, Heat exchanger, Water pumps, Safety valves, Pressure sensors.
| Feature | Description |
|---|---|
| Centrifugal Compressor | High-efficiency oil-free magnetic bearing technology |
| Variable Speed Drive | Optimizes energy consumption based on cooling demand |
| Control Panel | Touchscreen interface with real-time monitoring |
| Heat Exchanger | Enhanced tube design for maximum heat transfer |
| Water Pumps | Integrated pump system for chilled water circulation |
| Safety Valves | Pressure relief and emergency shutdown systems |
| Pressure Sensors | Continuous monitoring of system pressures |
| Remote Monitoring | Network connectivity for remote operation |
| Energy Optimization | Automatic load balancing and efficiency modes |
| Environmental Compliance | Uses low-GWP refrigerants |
Unpack and inspect all components. Ensure proper foundation and clearance.
WARNING! Chiller is extremely heavy; use proper lifting equipment. Ensure all electrical connections are made by qualified personnel.
Power on chiller; follow startup sequence on control panel.
CAUTION! Only trained technicians should perform initial setup. Follow all safety procedures.
Access control system via touchscreen panel. Main controls: POWER, START/STOP, MODE SELECT, ALARM RESET.
Control Panel: Display screen, Navigation buttons, Function keys, Emergency stop.
Operating Modes: COOLING, STANDBY, SERVICE. Settings: Temperature setpoint, Flow rates, Pressure limits, Schedule programming, Alarm settings, Maintenance reminders. Safety: High/low pressure cutouts, Motor protection, Flow switches, Temperature sensors.
Water Connections: Chilled water supply/return, Condenser water supply/return. Electrical: Main power, Control wiring, Network connections.
Tip: Use torque wrenches for all pipe connections to ensure proper sealing.
Supports automatic operation with manual override capability.
WARNING! Do not attempt to override safety controls. Follow proper shutdown procedures.
Multiple safety systems: High pressure cutout, Low pressure cutout, Motor overload, Flow switches, Temperature sensors, Emergency stop, Leak detection, Vibration monitoring.
Regular maintenance required for optimal performance. Unlock control panel before servicing.
Daily: Visual inspection, Check for leaks, Monitor performance
Monthly: Clean strainers, Check water treatment, Verify control operation
Annually: Complete system inspection, Refrigerant analysis, Motor bearing inspection, Control calibration
CAUTION! Only qualified technicians should perform maintenance. Follow lockout/tagout procedures.
UL/CSA certified; complies with ASHRAE standards and local building codes. EPA refrigerant handling certification required for service. Copyright © 2024 LG Electronics; all rights reserved. For technical support, visit www.LGcommercialhvac.com or contact 1-800-243-0000.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit will not start | Power supply/Safety lockout | Check main power; reset safety controls; verify flow switches. |
| High pressure alarm | Condenser issues | Clean condenser tubes; check water flow; verify fan operation. |
| Low pressure alarm | Refrigerant/Evaporator | Check refrigerant charge; inspect evaporator; verify expansion valve. |
| Vibration/noise | Motor/Compressor | Check motor bearings; inspect compressor alignment; verify mounting. |
| Reduced capacity | Fouling/Controls | Clean heat exchangers; check control settings; verify water treatment. |
Reset: Control panel > System > Reset after addressing fault condition.
Service: 1-800-243-0000; www.LGcommercialhvac.com