LG Ceiling Cassette Air Conditioners Manual Remote Control

The LG Ceiling Cassette Air Conditioners feature advanced climate control with remote operation capabilities. These systems provide efficient cooling and heating for commercial and residential spaces, offering multiple operation modes, temperature control, fan speed adjustment, timer functions, and energy-saving features. Below are key sections covering features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Guidelines 3. First-Time Setup 4. Technical Specifications 5. Remote Control Functions 6. Operation Modes 7. Maintenance Procedures 8. Error Codes & Diagnostics 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Ceiling cassette unit, wireless remote control, LCD display, temperature sensors, air filters, and multiple airflow directions.

FeatureDescription
Remote ControlWireless operation with LCD display and full function control
Operation ModesCool, Heat, Fan, Dry, Auto
Fan SpeedAuto, Low, Medium, High, Turbo
Temperature Control16°C - 30°C (60°F - 86°F) range
Timer Functions24-hour on/off timer
Airflow Direction4-way adjustable louvers
Sleep ModeAutomatic temperature adjustment for comfortable sleep
Energy SavingEco mode for reduced power consumption
Filter IndicatorReminder for regular filter cleaning
Self-DiagnosisAutomatic error detection and display

Installation Guidelines

Professional installation recommended. Ensure proper ceiling clearance and electrical requirements.

  1. Ceiling Preparation: Verify structural integrity and minimum 300mm clearance above ceiling.
  2. Electrical Connection: Connect to dedicated circuit with proper voltage (208-230V).
  3. Drainage Setup: Install condensate drain line with proper slope.
  4. Refrigerant Piping: Connect outdoor unit with flare connections.
  5. Remote Control: Install batteries and test communication range.

WARNING! Installation must be performed by qualified technicians only. Ensure proper electrical grounding.

First-Time Setup

Power on system and configure initial settings using remote control.

  1. Remote Control Setup: Insert batteries (AAA x2) and point at indoor unit.
  2. Initial Power: Turn on circuit breaker and wait for unit initialization.
  3. Mode Selection: Press MODE button to select desired operation (Cool/Heat/Fan).
  4. Temperature Setting: Use ▲▼ buttons to set desired temperature.
  5. Fan Speed: Adjust airflow with FAN button for optimal comfort.
  6. Timer Setup: Configure auto on/off times if needed.

CAUTION! Allow 5 minutes between power cycles to protect compressor.

Technical Specifications

Remote Control Functions

Complete control of all air conditioner functions through wireless remote.

Main Buttons: POWER, MODE, TEMP ▲▼, FAN, SWING, TIMER, SLEEP, RESET, FILTER, CLOCK.

Display Indicators: Current temperature, set temperature, operation mode, fan speed, timer status, filter alert, swing status. Special Functions: Auto restart after power failure, child lock, temperature unit conversion (°C/°F), buzzer on/off.

Operation Modes

Multiple operation modes for different comfort requirements.

  1. Cool Mode: Standard air conditioning with temperature control
  2. Heat Mode: Heating operation (heat pump models only)
  3. Fan Mode: Air circulation without cooling/heating
  4. Dry Mode: Dehumidification while maintaining temperature
  5. Auto Mode: Automatic selection of Cool/Heat based on room temperature
  6. Turbo Mode: Maximum cooling/heating capacity for rapid temperature change
  7. Quiet Mode: Reduced noise operation for nighttime use

Tip: Use Auto mode for energy-efficient operation throughout the day.

Maintenance Procedures

Regular maintenance ensures optimal performance and longevity.

  1. Air Filter Cleaning: Remove and clean every 2 weeks with vacuum or water
  2. Surface Cleaning: Wipe unit surface with soft dry cloth
  3. Drain Pan Inspection: Check for blockages monthly during heavy use
  4. Remote Control: Replace batteries every 6-12 months
  5. Professional Service: Annual inspection by qualified technician
  6. Winterization: For seasonal units, follow proper shutdown procedures

WARNING! Always disconnect power before performing any maintenance.

Error Codes & Diagnostics

Self-diagnosis system displays error codes for quick troubleshooting.

Error CodeDescriptionAction
CH 01Indoor unit communication errorCheck wiring connections
CH 02Outdoor unit communication errorVerify outdoor power
CH 07Inverter compressor errorProfessional service required
CH 09Discharge temperature sensor errorCheck sensor connection
CH 15Outdoor temperature sensor errorReplace sensor if faulty
CH 35Drain pump/floar switch errorClear drain line blockage

Care & Cleaning

Proper cleaning maintains efficiency and air quality.

Air Filters: Remove and clean every 2 weeks. Use vacuum cleaner or wash with mild detergent. Dry completely before reinstalling. Unit Surface: Wipe with soft, dry cloth. Do not use abrasive cleaners. Remote Control: Clean with dry cloth. Replace batteries when display dims. Drain System: Ensure drain line is clear of obstructions.

CAUTION! Do not use water or cleaning solutions on electrical components.

Regulatory Information

UL/ETL certified for safety standards. Energy Star compliant models available. EPA refrigerant handling certification required for service. Manufactured by LG Electronics. For technical support, contact LG Customer Service at 1-800-243-0000 or visit www.lg.com. All specifications subject to change without notice.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower supply/remoteCheck circuit breaker; replace remote batteries; ensure remote pointed at unit
Poor cooling/heatingDirty filters/settingsClean air filters; check temperature setting; ensure vents not blocked
Water leakageClogged drainClear drain line; check drain pan installation
Unusual noiseLoose parts/fanCheck for loose screws; ensure fan blades not obstructed
Remote not workingBatteries/obstaclesReplace batteries; remove obstacles; check operating distance
Error code displayedSystem faultNote error code; power cycle unit; contact service if persistent

Reset Procedure: Turn off power for 5 minutes, then restart. For remote reset, remove batteries for 30 seconds.

Service Contact: LG Customer Service 1-800-243-0000; www.lg.com

LG Ceiling Cassette Air Conditioners Manual Remote Control © - All Rights Reserved 2025