LG ARUN168BTE4 Installation Manual

The LG ARUN168BTE4 is a high-efficiency air conditioning unit designed for residential and commercial use. This installation manual provides comprehensive guidance for proper setup, including safety precautions, mounting instructions, electrical connections, refrigerant piping, drainage system setup, and initial startup procedures. Below are key sections covering all aspects of installation and initial configuration.

1. Safety Precautions 2. Package Contents 3. Unit Specifications 4. Installation Requirements 5. Mounting Instructions 6. Electrical Connections 7. Refrigerant Piping 8. Drainage System 9. Initial Startup 10. Commissioning 11. Troubleshooting

Safety Precautions

Before installation, read all safety instructions carefully to prevent injury and equipment damage.

Hazard TypePrecaution
Electrical ShockDisconnect power before installation; use proper grounding
Heavy LiftingUse proper lifting equipment; minimum 2-person lift required
Refrigerant HandlingWear protective gloves and goggles; avoid open flames
Sharp EdgesWear protective gloves during handling
High PressureCheck for leaks before full system pressurization

Package Contents

Unpack and verify all components are present before beginning installation.

  1. Outdoor Unit - ARUN168BTE4
  2. Installation manual and warranty card
  3. Mounting brackets and hardware kit
  4. Communication cable (3-core shielded)
  5. Drain hose extension
  6. Pipe cover set
  7. Remote controller with batteries

WARNING! Do not discard packaging until all components are verified. Report missing items immediately.

Unit Specifications

Installation Requirements

Ensure all prerequisites are met before installation begins.

  1. Clearance: Minimum 12 inches on all sides for airflow
  2. Mounting Surface: Solid concrete or reinforced wall
  3. Electrical: Dedicated circuit with proper disconnect
  4. Tools Required: Torque wrench, flaring tool, vacuum pump, manifold gauge
  5. Certification: Installer must be EPA certified for refrigerant handling

CAUTION! Installation by unqualified personnel may void warranty and create safety hazards.

Mounting Instructions

Proper mounting ensures stable operation and reduces vibration noise.

  1. Select mounting location meeting clearance requirements
  2. Mark and drill holes for mounting brackets
  3. Secure brackets with provided expansion bolts
  4. Lift unit onto brackets using proper equipment
  5. Secure unit to brackets with anti-vibration pads
  6. Ensure unit is level in all directions

Tip: Use spirit level to ensure perfect horizontal alignment.

Electrical Connections

Follow local electrical codes and manufacturer specifications.

ConnectionSpecification
Power Supply208-230V ±10%, 60Hz
Circuit Breaker20A dedicated
Wire Size12 AWG minimum
GroundingProper earth ground required
CommunicationShielded 3-core cable

WARNING! All electrical work must be performed by licensed electrician.

Refrigerant Piping

Proper piping ensures optimal performance and efficiency.

  1. Cut pipes to required length with pipe cutter
  2. Deburr and clean pipe ends thoroughly
  3. Flare connections to 45-degree angle
  4. Apply minimal refrigerant oil to flare surfaces
  5. Connect liquid and gas pipes with proper torque
  6. Perform leak test with nitrogen at 150 PSI
  7. Evacuate system to 500 microns vacuum

CAUTION! Over-torquing can damage flare connections and cause leaks.

Drainage System

Proper drainage prevents water damage and ensures efficient operation.

  1. Install drain hose with continuous downward slope
  2. Use insulated drain hose in unconditioned spaces
  3. Ensure drain trap is installed if required
  4. Test drainage with water before finalizing
  5. Secure all connections with hose clamps

Tip: Minimum slope of 1/4 inch per foot for proper drainage.

Initial Startup

Follow startup sequence carefully for proper system initialization.

  1. Verify all connections are secure and proper
  2. Remove service port caps slowly to release refrigerant
  3. Power on system at electrical disconnect
  4. Set remote controller to cooling mode
  5. Verify compressor and fan operation
  6. Check for abnormal noises or vibrations
  7. Measure temperature differential across coils

WARNING! Do not operate without proper refrigerant charge.

Commissioning

Final verification ensures optimal performance and warranty validation.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower supply/breakerCheck disconnect switch; verify circuit breaker; check voltage
Poor coolingRefrigerant charge/airflowCheck refrigerant levels; clean filters; verify airflow
Water leakageDrain blockageClear drain line; check slope; ensure proper trap
Unusual noiseVibration/componentCheck mounting; inspect fan blades; verify compressor
Error codesSensor/communicationRefer to service manual; check sensor connections

Reset: Power cycle unit; check error history in controller.

Service: Contact LG authorized service center for technical support.